Codmetel: HV004210

17th Edition Multifunction Installation with single-phase power quality measurement

COMBI421 tests to all local regulations (17th edition) and provides test results for complete documentation. It measures overall earth resistance, tests on RCDs type A and AC up to a rated current of 1A, Insulation up to 1000V, Continuity with 200mA and short-circuit currents, it also allows measuring and saving environmental parameters (illuminance, temperature), leakage current and the electric quantities active power, harmonics, power factor on single-phase systems and, last but not least, it offers the possibility of checking phase sequence only using one lead.

The internal memory allows saving the measurements carried out in order to subsequently transfer them onto the PC through the serial connection. The instrument has been provided with the innovative AUTO function: by selecting this function and only setting the value of RCD current, COMBI421, connected to a power outlet, carries out tests of overall earth resistance, on RCDs and insulation tests in a sequence. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple symbols OK or NOT OK.

Functions
TRMS  
Insulation with voltage 50, 100, 250, 500, 1000VDC  
Continuity of protective conductors with 200mA  
Tripping time and current of RCDs type B, A, AC Standard, Selective and Delayed up to 1A Only A, AC general and selective
Non-trip earth resistance  
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE  
Loop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution (0.1mΩ) With optional accessory IMP57
Contact voltage  
Phase sequence  
Leakage current with optional clamp meter  
Measurement of Voltage, Current, Active, Reactive, Apparent Power  
Measurement of Cosphi, Power Factor  
Voltage and current harmonics up to the 49th with THD 49th
AUTOMATIC test (Ra, RCD, Insulation)  
Measurement of environmental parameters (°C,°F, %RH, Lux)  
Test with remote lead PR400
Help on line on the display  
Internal memory for measured data saving  
Optical/USB serial port for PC connection  
Size (LxWx H) (mm) 222x162x57
Weight in grams (batteries included) 1200
Protection category CAT III 240V
Guidelines
  • CE MARK
  • CEI 64-8 612.6.2
  • 17th edition
  • CEI 64-8
  • CEI 64-8 612.3 .4 .5
  • CEI 64-8 612.6.1
  • CEI 64-8 612.6.3
  • EMC 2004/108/CE Directive
  • LVD 2006/95/CE Directive
  • DPR 462 del 22/10/2001
  • IEC/EN 61010-032
  • IEC/EN 61010-1
  • IEC/EN61557-1
  • IEC/EN61557-2
  • IEC/EN61557-3
  • IEC/EN61557-4
  • IEC/EN61557-6
  • IEC/EN61557-7
  • VDE 0100
  • CEI 64-8 612.2
  • EMC: IEC/EN61326
  • None